Megotec MTA300

Megotec_product_photoAnswering the need for a reliable lab analyzer pure water feed system, Hydro, Inc. Atlanta GA has developed the Megotec MTA series ultra pure water system. Megotec will distribute Type I Laboratory grade water as specified by ASTM, CAP/NCCLS and USP to chemistry analyzers and various other points of use within your laboratory. Producing water quality with minimal (low) background noise, Megotec may also be used with mass spectrometer equipment. With a production rate of 94.6 LPH, and the incorporation of our internal semi-automatic emergency bypass feature, Megotec can feed more than one (1) analyzer at any given time (depends upon certain equipment feed requirements). If you are interested in working with a personable water company that manufactures water systems in the U.S.A. (Georgia) and is backed by a personable service department with an outstanding Preventative Maintenance Agreement (PMA), then please contact Hydro, Inc.

1443648548_pdfClick Here to View Brochure

USP

United States Pharmacopoeia Standards (USP)

 Purified WaterWFI Water
Electrical Conductivity Max (µS/cm @ 25C)<1.3<1.3
Total Organic Carbon (TOC) (ppm)<0.5*<0.5*
Endotoxin (EU/ml)n/a<0.25
Bacteria (guideline only)<100 cfu/ml<10 cfu/100ml
* Or pass oxidisable substance test
When bacterial levels need to be controlled, reagent grade types should be further discussed as follows:
 Type AType BType C
Total Bacterial Count Max CFU/100ml1101000
Endotoxin max IU.ml0.030.25-

CLSI-CAP

Clinical and Laboratory Standards Institute (CLSI) (CAP)
  CLRWType IType IIType III
BacteriaBacteria (CFU/ml)<10<1<100<1000
Pyrogens(Eu/ML)-<0.03n/an/a
IonsResistivity (MΩ-cm @ 25C)>10>18>1>0.05 K50Ω
ColloidsSilica (ppb)-<10<100<1000
ParticlesParticles >0.2 µm (units/mL)Include 0.22 µ filtration<1 (0.22 µ filtration required)n/an/a
OrganicsTotal Organic Carbon ppb<500<10<50<200
The above values are meant to be used as guidelines; some applications may require additional treatment.

ASTM Standards

American Society for Testing and Materials (ASTM)


Standard Specification for Reagent Grade Water
 Type IType IIType IIIType Iv
Electrical Conductivity Max (pX/cm @ 25C)0.0561.00.255.0
Electrical Resistivity Min (MOhms-cm @ 25C)181.04.00.2
pH @ 25&#176C---5.0-8.0
TOC max (µg/L)10050200No Limit
Sodium max (µg/L)151050
Silica max. (µg/L)33500No Limit
Chloride max (µg/L)151050
When bacterial levels need to be controlled, reagent grade types should be further discussed as follows:
 Type AType BType C
Total Bacterial Count Max CFU/100ml1101000
Endotoxin max. IU.ml0.030.025-

Ozone Purification

This is a two page document. Click a corner to flip to another page.

Ultraviolet Sterilization

UV SystemContact us for your specific needs.

UV System 1Contact us for your specific needs.

https://hydroinc.net/644-2/

Hanovia UVContact us for your specific needs.

https://hydroinc.net/642-2/

UV System 2Contact us for your specific needs.

https://hydroinc.net/636-2/

White-Blue Tanks

https://hydroinc.net/634-2/

  • Go to page 1
  • Go to page 2
  • Go to page 3
  • Interim pages omitted …
  • Go to page 8
  • Go to Next Page »
117 Merchants Park Drive
Hoschton, GA 30548
(706) 654-5333
Metro Atlanta
800-579-6869
Outside Metro Atlanta

© 2023 Hydro, Inc.
Water Quality Specialists

Definitioner

Sodium
an ion found in natural water supplies, and introduced to water in the ion exchange water softening process.
PH
the reciprocal of the logarithm of the hydrogen ion concentration. The ph scale is from zero to 14,and 7.0 is the neutral point, indicating the presence of equal concentrations of free hydrogen and hydroxide ions, ph values below 7.0 indicate increasing acidity, and ph values above 7.0 indicate increasing base concentrations.
Conductivity
the quality or power to carry electrical current; in water, the conductivity is related to the concentration of ions capable of carrying electrical current.